WEKO3
アイテム
遠隔容積脈波を用いた交感神経活動の評価
https://maebashi-it.repo.nii.ac.jp/records/40
https://maebashi-it.repo.nii.ac.jp/records/4025244e40-665b-4cd5-8fa2-65c911024784
名前 / ファイル | ライセンス | アクション |
---|---|---|
041 遠隔容積脈波を用いた交感神経活動の評価(野村)(P19-P22).pdf (563.0 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper_02(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-24 | |||||
タイトル | ||||||
タイトル | 遠隔容積脈波を用いた交感神経活動の評価 | |||||
その他のタイトル | ||||||
その他のタイトル | Evaluation of sympathetic nerve activity using plethysmographic signals measured remotely | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 光電容積脈波 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 遠隔容積脈波 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 遠隔バイタルモニタ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 交感神経活動 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 脈拍 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 呼吸 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 心電図 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 唾液アミラーゼ活性 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | photoplethysmogram | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | sympathetic nerve | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | heart rate | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | respiration | |||||
著者 |
野村, 保友
× 野村, 保友× 神田, 真理子× 清, 文美× 松尾, 篤史× ノムラ, ヤストモ× カンダ, マリコ× セイ, アヤミ× マツオ, アツシ× Nomura, Yasutomo× Kanda, Mariko× Sei, Ayami× Matsuo, Atsushi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Plethysmographic signals were detected remotely (0.5 m) under the standard room light by the use of a built-in webcam on note PC. The RGB color movies were recorded at video-rate and the region of interest was set to the forehead of each subject. Changes in the average intensity of G channel appeared to be consistent with pulsation, respiration and the body movement. When the time series data was subjected to Fourier analysis, we found the characteristic peaks corresponding to the frequency of heart rate and respiration in the spectra. As for the B channel, we observed the respiration signal but the very weak signal of pulsation. Neither were almost contained in the R channel. In subjects that kept running for 3 minutes, the exercise increased the frequency of the plethysmographic signal measured remotely, suggesting the sympathetic nerve activation. This was confirmed by the increase in the LF/HF ratio of electrocardiogram and the salivary amylase activity. Furthermore, the exercise increased pulsation as well as respiration measured remotely. The remote vital monitor would be one of the evaluation methods of sympathetic nerve activity and be especially useful for the person who has difficulty wearing the sensor for sympathetic nerve activity. | |||||
書誌情報 | 発行日 2017-03-31 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1343-8867 | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Thesis or Dissertation | |||||
更新日 | ||||||
日付 | 2017-11-26 | |||||
日付タイプ | Created |